In response to the OpenSSL* advisory (CVE-2010-0740), Intel is releasing an update to the Intel® Active Management Technology (Intel® AMT) Software Development Kit (SDK)and Intel® Setup and Configuration Service (Intel® SCS) to mitigate this vulnerability. This issue does not affect the Intel® Active Management Technology implementation on Intel® vPro TM technology based platforms.
The Intel® AMT SDK is the development framework for the Independent Software Vendors (ISVs) to develop manageability applications that interact with Intel® AMT-enabled systems.
Intel® SCS provides the ISVs with the tools to integrate setup and configuration capabilities into their products to setup (provision) Intel® Active Management Technology (Intel® AMT) devices.
Updated versions of Intel® AMT SDK and Intel® SCS which correct the potential denial-of-service vulnerability in OpenSSL* are available for the ISVs. |
The vulnerability in the OpenSSL* library could allow a remote attacker to cause denial-of-service. Intel is releasing updated Intel® AMT SDK and Intel® SCS which incorporate the updated OpenSSL* library to mitigate this issue. It is expected that the ISVs would then provide corresponding software updates to their affected application users.
This issue does not affect Intel® Active Management Technology implementation on Intel® vProTM technology based platforms. |
The ISVs utilizing products below are potentially affected by this issue.
|
Software Tools
|
Version
|
|
Intel® AMT SDK
|
Prior to the public release of version 6.0 (V6.C1076)
|
|
Intel® SCS
|
Version 5.0 and 6.0
|
|
Intel® AMT SDK
For Windows*, the ISVs should replace KVM and Redirection libraries:
· Redirection library:
o imrsdk.dll
o imrsdk_x64.dll
· KVM library:
o kvmlib.dll & KVMCustomTransport.dll (applicable to both 32 and 64 bit versions)
o Alternately, ISVs could recompile the KVM code using the updated Intel® AMT SDK which incorporates the updated OpenSSL* library.
For Linux*:
· KVM library: The ISVs recompile the KVM code using the updated Intel® AMT SDK.
Redirection library: Requires the OpenSSL* library installed in the system to be updated.
The users of the management console application for Intel® AMT should contact the respective application provider to determine if their application may be affected.
Intel® SCS
The users of the setup and configuration tool for Intel® AMT should contact the respective application provider to determine if their application may be affected.
* other brands and names may be claimed as the property of others. |
Revision | Date | Description | 1.0 | 20-July-2010 | Initial release |
|